跳转到主要Content
Raytron Technical Review RESEARCH ARTICLE WP-08-03

GB/T 29197standards解读

GB/T 29197 Standard Interpretation

RAYTRON Technical Team1

1RAYTRON Group, China

发布日期: March 2026 版本: 1.0
DOI: 10.1000/raytron.WP-08-03

1. Standard Overview

1.1 Basic Information

ItemDetails
Standard NumberGB/T 29197-2012
Standard NameCCA线 (Copper-Clad Aluminum Wire)
PublisherStandardization Administration of China
Implementation DateJuly 1, 2013
Standard TypeRecommended national standard

1.2 Standard Positioning

PositionDescription
Domestic marketUnified technical specification
Trade basisQuality supervision and acceptance
International alignmentHarmonized with international standards

Chart placeholder

MEDIA TODO
Figure 1 GB/T 29197 standard development background

2. Product Classification

2.1 By Conductivity

Grade CodeConductivity (%IACS)Copper Volume (%)
CCA-156215
CCA-207020
CCA-258025

2.2 By Temper

Temper CodeNameCharacteristics
OAnnealedSoft, easy to process
HHardHigh strength, for overhead use

2.3 By Application

CategoryCodeTypical Application
ElectricalEWire and cable conductors
ElectronicECElectronic wire, coils

3. Technical Requirements

3.1 Dimensional Specifications

SeriesSpecifications (mm)
Fine wire0.10, 0.12, 0.15, 0.18, 0.20...
Medium wire0.50, 0.60, 0.80, 1.00, 1.20...
Coarse wire3.00, 4.00, 5.00, 6.00...

3.2 Tolerance Requirements

Diameter Range (mm)Tolerance (mm)
0.10-0.40±0.004
0.41-1.00±0.008
1.01-2.50±0.015
2.51-5.00±0.025
5.01-8.00±0.040

3.3 Mechanical Properties

TemperDiameter (mm)Tensile Strength (MPa)Elongation (%)
Hard (H)≤0.50138-207≥1.0
Hard (H)0.51-1.00124-193≥1.5
Annealed (O)≤1.00≤152≥8.0
Annealed (O)>1.00≤138≥10.0

3.4 Electrical Properties

Diameter (mm)CCA-15 (Ω/km)CCA-20 (Ω/km)CCA-25 (Ω/km)
0.500.1360.1210.105
1.000.0340.0300.026
1.500.0150.0130.012

Chart placeholder

MEDIA TODO
Figure 2 GB/T 29197 mechanical property requirements by diameter

4. Test Methods

4.1 Dimensional Measurement

ParameterSpecification
ToolOutside micrometer
Accuracy0.001mm
MethodTwo perpendicular measurements

4.2 Resistance Test

ParameterSpecification
StandardGB/T 3048.4
MethodFour-wire method
Temperature correctionConvert to 20°C

4.3 Copper Layer Measurement

MethodStandard
MetallographicGB/T 6462
Eddy currentQuick detection
Weight methodVolume calculation

5. International Comparison

5.1 vs ASTM B566

AspectGB/T 29197ASTM B566
Conductivity grades3 levels (62/70/80)4 levels (62/70/80/90)
Copper volume definitionDifferent from ASTMStandard definition
Size seriesPrimarily metricImperial + metric
Test methodsReferences GB standardsASTM methods

5.2 vs IEC 62641

AspectGB/T 29197IEC 62641
Conductivity gradesBasically equivalentBasically equivalent
Test methodsReferences GBReferences IEC
International recognitionPrimarily ChinaInternational

Diagram placeholder

MEDIA TODO
Figure 3 International standards comparison matrix

6. Conclusion

6.1 Summary

AspectKey Point
ScopeComprehensive CCA wire specification for China
AlignmentHarmonized with international standards
ApplicationQuality control and trade acceptance

6.2 Implementation Guidance

  • Verify conductivity grade matches order requirements
  • Check appearance quality and dimensions
  • Review test reports and sample key parameters

7. References

  1. GB/T 29197-2012 CCA线
  2. ASTM B566-04(2020) Standard Specification for Copper-Clad Aluminum Wire
  3. IEC 62641:2013 Copper-clad aluminium for electrical purposes

FAQ

What is the difference between GB/T 29197 and IEC 62641?

GB/T 29197 is the Chinese national standard primarily used in the domestic market, while IEC 62641 is an international standard. Both are technically equivalent for conductivity grades, but GB/T 29197 references Chinese GB test methods, whereas IEC 62641 references IEC methods. For export markets, IEC 62641 certification is recommended.

Is GB/T 29197 certification mandatory in China?

GB/T 29197 is a recommended (not mandatory) national standard. However, it is widely used as the technical basis for product quality acceptance, tender requirements, and CCC certification for cable products using CCA conductors.

How to select the right CCA grade according to GB/T 29197?

Select based on application requirements: CCA-15 for general low-voltage distribution and building wiring, CCA-20 for coaxial cables and high-frequency applications, and CCA-25 for applications requiring higher conductivity. Consider both electrical performance and cost-effectiveness.

徐高磊

(Gaolei Xu)

资深材料科学家

资质荣誉

  • 锐创集团 CTO
  • 浙江省高层次人才特殊支持计划青年人才
  • 绍兴市"科技副总"
  • 绍兴市科技特派员
  • 全国有色金属standards化技术委员会重金属分技术委员会(TC243/SC2)委员

国家standards(主要起草人) 查看官方

发明专利 检索专利

专业Section

CCA(CCA)技术 铜包钢(CCS)制造工艺 双金属复合材料 光伏焊带技术 电动汽车电池极耳材料 连续挤压技术

代表性论文

  • 轧制法制造金属层状复合材料的研究与Applications,《铝加工》2008年第3期
  • 铜铝复合带退火工艺的研究
  • 电缆用铜铝复合带制备工艺研究
  • 轧制铜/铝复合带材在退火过程中的界面组织演变

徐高磊先生是有色金属加工Section的知名专家,拥有超过15年的丰富经验。他入选浙江省高层次人才特殊支持计划青年人才。他在双金属复合材料技术开发方面做出了重要贡献,并为中国铜及双金属材料的standards化工作做出了重要贡献。

点击standards/专利编号可查看官方文档

马上联系锐创,让每米材料为您创造更高价值

我们的技术团队是中国多项国家标准的制定者,拥有30年行业经验和34项专利,为您提供专业的双金属复合材料解决方案。立即联系我们,获取技术支持和产品报价。

在线联系

通常在24小时内回复

扫码添加企业微信

扫码添加企业微信

电话咨询
+86 186 5753 6277
Get Quote WhatsApp咨询